Is a ruggedized BackPlane military compliant power supply built for deployable
and harsh environment applications where operational reliability is primary concern.
AC to DC Power Supply
PowergridM AC to DC Power Supply – BackPlane Module BPM Custom UPS
The PowergridM DCPS-BPM is a ruggedized BackPlane ready military compliant power supply system built for deployable and harsh environment applications where operational reliability is primary concern. Custom UPS
The PowergridM DCPS-BPM48 is built on that same rugged chassis design incorporated into all PowergridM products hosting a very Low EMI signature and designed for high Reliability operations. This DC power supply system shares most of the operational characteristics of the PowergridM Product Line including universal input power and an optional VDC input power capability.
MIL STD 461 UPS | MIL STD 810 UPS
EMI / EMC – PowergridM UPS system has been designed to comply with all the radiated emissions, susceptibility and conductive emissions requirement of the applicable sections of MIL STD 461F. The following is a list of methods used for controlling emissions: RE102 | CE102 | CS101 | CS114 | CS115 | CS116 | RS103 DESIGNED TO MEET
Environmental MIL-STD-810G: Humidity, Altitude, Sand and Dust, Shock and Vibration, Temperature.
Highlights
• BPM Ready 1U AC to DC power supply system.
• Provide 1000, 2000, or 4000 Watts
• 12V, 24V, 28V, or 48VDC output options.
• In-System redundant configurations available.
• Over voltage, over current and over temperature.
• Short circuit protection.
1U 800 watts UPS – Standalone Stackable to:
800 watts UPS | 1600 watts UPS | 2400 watts UPS | 3200 watts UPS
1U 800 watts UPS – BackPlane Stackable to:
1600 watts UPS | 2400 watts UPS | 3200 watts UPS | 4000 watts UPS
1U 1000 watts UPS – Standalone Stackable to:
1000 watts UPS | 2000 watts UPS | 3000 watts UPS | 4000 watts UPS
1U 1500 VA UPS – Standalone Stackable to:
1500 VA UPS | 3000 VA UPS | 4500 VA UPS | 6000 VA UPS
1U 1200 watts UPS – Standalone Stackable to:
1200 watts UPS | 2400 watts UPS | 3600 watts UPS | 4800 watts UPS
1U 1500 VA UPS – Backplane Stackable to:
1500 VA UPS | 3000 VA UPS | 4500 VA UPS | 6000 VA UPS | 7200 VA UPS
1U 1200 watts UPS – Backplane Stackable to:
1200 watts UPS | 2400 watts UPS | 3600 watts UPS | 4800 watts UPS | 6000 watts UPS
2U 3000 VA UPS – Standalone Stackable to:
3000 VA UPS | 6000 VA UPS | 9000 VA UPS
2U 2400 watts UPS – Stackable to:
2400 watts UPS | 4800 watts UPS | 7200 watts UPS
-
• Input Voltage: VAC 90-264, 47-63Hz, (400 Hz @115V only).
• Efficiency: 85% Typical.
• Hold Up Time: >16 mS at 80% Load.
• Operating Temperature: -20 to 60ºC Standard (De-rating from 50ºC to 60ºC).
• Storage Temperature: -20 to 70ºC all Modules.
• Load Regulation: 1% Standard.
• Line Regulation: 1% Standard.
• Thermal Protection: Over Temperature Shut down on each Output.• Humidity: 5-95% Non-Condensing.
• Altitude: 10,000 Ft Operating – 40,000 Ft Non-Operating.
• Humidity: 0-95% non-condensing.
• Fungus: In accordance with MIL-STD-810G.
• Sand & Dust: MIL-STD-810G (with optional filters).
• Vibration: Designed for MIL-STD-810G.
• Functional Shock: Designed for MIL-STD-810G. -